Piled Foundation Design as Reflected in Codes and Standards
Bengt H. Fellenius, Bengt H. Fellenius Consultants, Canada

An example from a guidelines document for the Eurocode is discussed that addresses design for geotechnical strength of piled foundations in settling soil, generating drag force and downdrag. A modified example of geotechnical response is then analyzed in a failure mode, Ultimate Limit States (ULS), and stationary long-term state, Serviceable Limit States (SLS). It is shown that the Eurocode principles, when applied to correctly determined forces, results in an irrational and costly design. The results of the analysis of the modified example are applied to eight different codes pertaining to piled foundations from USA, Canada, Europe, and other countries. Several of the codes require that the drag force be included as a load in a ULS design, which an absurd and costly requirement, in some codes, in one case made even worse by combining drag force with live load. A major weakness of almost all codes is their minimal treatment and sometimes total absence of aspects of settlement of piled foundation. In contrast, my main argument is that design for capacity, whether in working stress approach, or by LFRD or ULS approaches, is not always safe unless a thorough settlement analysis shows that the design also meets the requirements of the SLS.


 article #1973; publication #100 (IC-2014)